The Sentry Basic CDU offers different input connections to distribute power from 208V, single phase 20 or 30-Amp input feeds. The Sentry Basic CDU meets the criteria of Branch Circuit Protection by providing overcurrent protection with UL-listed circuit breakers for each branch circuit.
The Sentry Basic Cabinet Power Distribution Unit (CDU) family provides both a reliable and economical solution for your basic power needs.
Branch Circuit Protection
This rack PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
Flexible Mounting
This rack PDU includes standard button mounts along with provisions for custom mounting brackets (contact Server Technology for details).
High Retention Locking Outlets
Receptacles have high retention and are compatible with P-Lock type power cords.
Color Identification
Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.
Product List
Model # | Total Outlets | Input Power Capacity | Input Nominal Voltage | Input Current | Input Current Rated | Phase | Plug Type | Branch Monitoring | Outlet Monitoring | Dimensions | Mounting | PRO2 | Input Monitoring | Alt Phase |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CB-12H1-C20 | 12 | 1.9 | 120 | 20 | 16 | 1-Phase (L-N) | IEC C20 100-120V Inlet | None | None | 17.0 x 1.75 x 2.25 in. (58.0 x 45.0 x 432.0 mm.) | 1U Horizontal | CDU1 | None | No |
CB-12H2-L630 | 12 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | None | None | 17.0 x 1.75 x 2.25 in. (58.0 x 45.0 x 432.0 mm.) | 1U Horizontal | CDU1 | None | No |
CB-12H2-C20 | 12 | 2.8 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 200-240V Inlet | None | None | 17.0 x 1.75 x 2.25 in. (58.0 x 45.0 x 432.0 mm.) | 1U Horizontal | CDU1 | None | No |
CB-12H1-L530 | 12 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | None | None | 17.2 x 1.75 x 2.25 in. (58.0 x 45.0 x 437.0 mm.) | 1U Horizontal | CDU1 | None | No |
CB-24V1-C20 | 24 | 1.9 | 120 | 20 | 16 | 1-Phase (L-N) | IEC C20 100-120V Inlet | None | None | 1.75 x 31.25 x 2.25 in. (58.0 x 794.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-24V1-L530 | 24 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | None | None | 1.75 x 31.25 x 2.25 in. (58.0 x 794.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-24VDE403-001 | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | None | None | 1.75 x 50.0 x 1.75 in. (45.0 x 1270.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-24VYM403-001 | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | None | None | 1.75 x 50.0 x 1.75 in. (45.0 x 1270.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-24VDD403-001 | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Delta (L-L) | NEMA L15-20P | None | None | 1.75 x 50.0 x 1.75 in. (45.0 x 1270.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-24VYL403-001 | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | None | None | 1.75 x 50.0 x 1.75 in. (45.0 x 1270.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-24VEK401-001 | 24 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | None | None | 1.75 x 34.0 x 2.0 in. (51.0 x 864.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-24V2A401-001 | 24 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 200-240V Inlet | None | None | 1.75 x 34.0 x 2.0 in. (51.0 x 864.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-24VEA401-001 | 24 | 3.6 | 230 | 16 | 16 | 1-Phase (L-N) | IEC C20 200-240V Inlet | None | None | 1.75 x 34.0 x 2.0 in. (51.0 x 864.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-24V2C401-001 | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | None | None | 1.75 x 34.0 x 2.0 in. (51.0 x 864.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-26VEKE01F6 | 26 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | None | None | 1.75 x 35.5 x 1.75 in. (45.0 x 902.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-26V2CE01F6 | 26 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | None | None | 1.75 x 35.5 x 1.75 in. (45.0 x 902.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-26V0AE01F6 | 26 | 3.6 | 208 | 16 | 16 | 1-Phase (L-N) | IEC C20 100-240V Inlet | None | None | 1.75 x 35.5 x 1.75 in. (45.0 x 902.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-24VDX403A9 | 24 | 17.3 | 208 | 60 | 48 | 3-Phase Delta (L-L) | 208V Delta 60A IEC 60309 3P+G 9Hr | None | None | 1.75 x 65.0 x 3.5 in. (89.0 x 1651.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-24VDV403A9 | 24 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 | None | None | 1.75 x 65.0 x 3.5 in. (89.0 x 1651.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-24VYY403A9 | 24 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | None | None | 1.75 x 65.0 x 3.5 in. (89.0 x 1651.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-12V2AH01 | 12 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 200-240V Inlet | None | None | 1.75 x 25.0 x 2.25 in. (58.0 x 635.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
CB-12V2CH01 | 12 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | None | None | 1.75 x 25.0 x 2.25 in. (58.0 x 635.0 x 45.0 mm.) | 0U Vertical | CDU1 | None | No |
Power is a critical resource and an expensive reality.
There’s a reason we’re the #1 choice of so many IT professionals.
Contact us and experience why.
Questions? Call us.
We’re here to assist you with optimizing your power backup, distribution, and measurement for a more efficient server room.
1-800-638-2638
Explore 42U Solutions
One of our data center solutions specialists will work together with you to find the optimal solution for your system.